Why RECD Test Results Can Differ Between Laboratories


When an organisation evaluates a Retrofit Emission Control Device (RECD) for a diesel generator, laboratory testing plays an important role in understanding emission performance. However, it is not unusual for two laboratories to report different results for what appears to be the same DG set and RECD. At first glance, this can create confusion and raise questions about which report should be trusted.

In many cases, different results do not automatically mean that one laboratory made a mistake. Testing conditions, measurement methods, operating load, reporting basis and measurement uncertainty can all influence the final numbers.

Understanding these factors makes it easier to interpret RECD test reports correctly.

Different Testing Objectives Can Produce Different Results

The first point to check is whether both laboratories were actually answering the same question.

An RECD may be tested for several reasons, including product evaluation, site acceptance, performance verification or routine stack monitoring. A laboratory performing a controlled before-and-after test may calculate particulate reduction, while another laboratory conducting routine monitoring may only report the downstream concentration.

These results should not automatically be compared as though they represent identical measurements.

For a more detailed approach to comparing reports, see Aceget's guide on how to compare RECD test results from different laboratories.

Testing Methods Can Influence the Numbers

Laboratory methodology is another important factor. Even when two laboratories test the same DG set, differences in sampling procedures can affect the reported result.

Important points include:

  • Particulate measurement method

  • Sampling location

  • Sampling duration

  • Number of test runs

  • Probe and filter temperature

  • Gas measurement procedure

  • Isokinetic sampling performance

  • Upstream and downstream measurement arrangement

A report should therefore be reviewed beyond its final result table. Raw data, sampling information and calibration records can provide valuable context for understanding why two results may differ.

DG Set Load Must Be Considered

Generator operating conditions have a major influence on emission measurements. A DG set tested at 40% load may not produce the same exhaust characteristics as the same generator operating at 60%, 75% or another load.

Exhaust temperature, engine operating conditions and particulate formation can change with load. The operating state of the RECD can also influence the measured result.

For this reason, comparing a commissioning test performed at one load with a later monitoring test performed at another load may produce misleading conclusions.

A meaningful performance comparison should ideally use matched operating conditions and clearly documented load values.

Reporting Basis Can Create Apparent Differences

Two laboratories may report technically valid results using different reference conditions.

For example, one report may provide a concentration on a dry basis while another uses a wet basis. Oxygen correction can also make a significant difference. Temperature and pressure reference conditions should be checked as well.

Before comparing values, verify:

  • Wet or dry basis

  • Reference oxygen concentration

  • Reference temperature

  • Reference pressure

  • Concentration versus mass emission rate

  • Units used for reporting

Normalising results to a common basis can sometimes explain a large part of the apparent difference.

Measurement Uncertainty Matters

No measurement is perfectly exact. Laboratory results contain uncertainty arising from instruments, sampling, calibration, weighing, environmental conditions and other factors.

Therefore, comparing two numbers simply by subtracting one from the other may not provide a complete picture.

A better approach is to consider the uncertainty associated with each measurement. The internationally recognised Guide to the Expression of Uncertainty in Measurement (GUM) provides a framework for evaluating measurement uncertainty. The JCGM publications are maintained through the BIPM-led metrology framework. BIPM

For testing and calibration activities in India, it is also useful to review the scope of laboratory accreditation. NABL India provides accreditation services for testing and calibration laboratories and publishes relevant accreditation documents. NABL India

Compare Complete Tests Whenever Possible

If two laboratories have independently performed complete before-and-after tests, comparing their calculated reduction percentages can be more meaningful than mixing individual numbers from different reports.

For example, if Laboratory A records an emission reduction of 75% and Laboratory B records 72%, the difference may be relatively small even if their absolute concentration values are different.

However, taking the baseline result from one laboratory and the post-RECD result from another can create a misleading reduction calculation, particularly when the tests were performed under different loads or reference conditions.

Check Calibration and Documentation

Calibration records should also be reviewed when investigating inconsistent results.

Useful documents may include:

  • Instrument calibration certificates

  • Sampling equipment details

  • Raw measurement data

  • Filter information

  • Gas analyser readings

  • Load records

  • Sampling conditions

  • Test method references

  • Laboratory accreditation scope

  • Measurement uncertainty information

A well-documented report makes it easier to reproduce calculations and understand the basis of the final result.

When Should a New Test Be Considered?

If two reports remain significantly different after checking methodology, operating conditions, reference basis and uncertainty, further investigation may be necessary.

For important disputes involving acceptance testing, regulatory interpretation or equipment performance, a controlled joint test can be useful. Ideally, both parties should agree beforehand on the test method, operating load, sampling locations, reference conditions and reporting format.

This reduces the possibility of comparing two fundamentally different tests.

Final Thoughts

Different RECD laboratory results do not necessarily indicate poor testing or RECD performance. In many situations, the difference comes from variations in test conditions, measurement methods, operating load, reporting basis or uncertainty.

The best approach is to examine the complete reports, normalise the results where appropriate and compare tests performed under genuinely comparable conditions. When both laboratories conduct properly controlled before-and-after testing, their calculated reduction values can provide a much clearer picture of RECD performance.